<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-14T02:38:06Z</responseDate>
  <request identifier="oai:figshare.com:article/33985834" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33985834</identifier>
        <datestamp>2026-09-24T13:47:24Z</datestamp>
        <setSpec>category_26779</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>ANSI/ASHRAE Standard 15-2024 &amp; UL 60335-2-40 Low-GWP A2L Refrigerant Flammability, Charge Limits, &amp; Temperature Glide Benchmark Dataset (200 Vectors)</dc:title>
          <dc:creator>Miad Saadidi (24671005)</dc:creator>
          <dc:subject>Mechanical engineering not elsewhere classified</dc:subject>
          <dc:subject>HVAC system model</dc:subject>
          <dc:description>&lt;p dir="ltr"&gt;This open engineering benchmark dataset contains 200 deterministic state vectors evaluating thermodynamic phase equilibrium, Lower Flammability Limits (LFL), and maximum allowable charge sizing for next-generation low-GWP A2L refrigerants (R-454B, R-32, R-454A, and R-1234yf) alongside baseline R-410A under ANSI/ASHRAE Standard 15-2024 Section 7 and UL 60335-2-40 (4th Edition) Annex GG.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;Under the EPA AIM Act 40 CFR Part 84, comfort cooling stationary equipment manufactured after January 1, 2025/2026 must utilize refrigerants with GWP &lt; 700. This dataset tabulates passive unmitigated charge limits (m1 = 0.20 × LFL × V_eff), required minimum room volumes and floor areas across 8 architectural space volumes (250 to 5,000 cu ft) and 5 system charge thresholds (2.5 to 12.0 lb), and classifies required safety mitigation tiers (Tier 0 passive, Tier 1 continuous circulation airflow, and Tier 2 active Refrigerant Detection Systems with interlocked mechanical ventilation). In addition, zeotropic temperature glide (ΔT_glide = T_dew - T_bubble) and thermodynamic reference points for superheat (dew point) and subcooling (bubble point) are explicitly mapped per NIST REFPROP formulations.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;File Asset: public/datasets/a2l_refrigerant_flammability_glide_benchmark_2026.csv (200 rows, 44.8 KB).&lt;/p&gt;&lt;p dir="ltr"&gt;License: Creative Commons Attribution 4.0 International (CC BY 4.0).&lt;/p&gt;</dc:description>
          <dc:date>2026-09-24T13:47:24Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.6084/m9.figshare.33985834.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/ANSI_ASHRAE_Standard_15-2024_UL_60335-2-40_Low-GWP_A2L_Refrigerant_Flammability_Charge_Limits_Temperature_Glide_Benchmark_Dataset_200_Vectors_/33985834</dc:relation>