<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-14T02:37:22Z</responseDate>
  <request identifier="oai:figshare.com:article/33972925" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33972925</identifier>
        <datestamp>2026-09-23T11:38:51Z</datestamp>
        <setSpec>category_140</setSpec>
        <setSpec>portal_316</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Supplementary file 1_Expanding indications for transcatheter aortic valve implantation: time for valve-in-valve in mechanical prosthesis? A systematic review and meta-analysis.docx</dc:title>
          <dc:creator>Julio Ruiz-Ruiz (25096963)</dc:creator>
          <dc:creator>Akash Jain (2105653)</dc:creator>
          <dc:creator>Mario García Gómez (25096966)</dc:creator>
          <dc:creator>Alexander Stepanenko (16704306)</dc:creator>
          <dc:creator>Filippo Pensotti (25096969)</dc:creator>
          <dc:creator>Marcelo Rodríguez (3470873)</dc:creator>
          <dc:creator>Carlos Real (9410021)</dc:creator>
          <dc:creator>Carlos Cortés Villar (15453573)</dc:creator>
          <dc:creator>Carlos Galán-Arriola (25096972)</dc:creator>
          <dc:creator>Blanca De Prada Martín (25096975)</dc:creator>
          <dc:creator>Manuel Carrasco Moraleja (25096978)</dc:creator>
          <dc:creator>Robert Willian Anastácio Alcântara (25096981)</dc:creator>
          <dc:creator>Alberto San Román (25096984)</dc:creator>
          <dc:creator>Borja Ibañez (11544537)</dc:creator>
          <dc:creator>Ignacio Amat-Santos (10376796)</dc:creator>
          <dc:subject>Cardiology</dc:subject>
          <dc:subject>bleeding complications</dc:subject>
          <dc:subject>mechanical aortic prosthesis</dc:subject>
          <dc:subject>TAVI</dc:subject>
          <dc:subject>transcatheter aortic valve implantation</dc:subject>
          <dc:subject>valve-in valve</dc:subject>
          <dc:description>Aims&lt;p&gt;Following the recent first-in-human experience of Valve in Mechanical Valve (ViMech), interest has emerged in understanding how frequently such an approach might be required in clinical practice. We performed an exploratory meta-analysis to characterize the long-term burden of valve-related complications and reintervention after mechanical aortic valve replacement.&lt;/p&gt;Methods&lt;p&gt;Systematic literature search identified studies reporting outcomes of the five most used mechanical aortic valve models (Medtronic/ATS, St. Jude, Carbomedics, Bicarbon, On-X). Descriptive analysis and random-effects meta-analysis assessed late all-cause and valve-related mortality and complications (bleeding, thromboembolism, valve thrombosis, endocarditis, paravalvular leak, reintervention), expressed per 100 patient-years.&lt;/p&gt;Results&lt;p&gt;Thirty-two studies encompassing 24,960 patients undergoing mechanical valve replacement were assessed. Isolated mechanical aortic valve replacement was reported in all 32 studies (13,890 patients; 98,987 patient-years; mean follow-up 7.1 years); mean age at implantation was 57.9 years (95% CI 56.3–59.6) and 43% (38–49) were female. Pooled all-cause mortality was 2.39 per 100 patient-years (95% CI 1.92–2.99) and valve-related mortality was 0.55 (0.41–0.73) per 100 patient-years. Bleeding (0.22 [0.16–0.30]) and thromboembolic events (0.18 [0.12–0.25]) were the leading causes of valve-related death. Thromboembolic events (0.94 [0.77–1.14]) and bleeding (0.85 [0.65–1.10]) were the most frequent non-fatal complications, considerably more common than reintervention (0.36 [0.28–0.48] per 100 patient-years). All-cause mortality and complication rates were broadly similar across valve models.&lt;/p&gt;Conclusions&lt;p&gt;Mechanical aortic valves show excellent long-term durability with low reintervention rates. Nevertheless, valve-related complications, mainly bleeding and thromboembolism, suggest a small but clinically relevant population in whom redo surgery may carry substantial risk, providing epidemiological context for emerging Valve in Mechanical Valve strategies.&lt;/p&gt;Systematic Review Registration&lt;p&gt;https://www.crd.york.ac.uk/PROSPERO/view/CRD420251002419, identifier CRD420251002419.&lt;/p&gt;</dc:description>
          <dc:date>2026-09-23T11:38:51Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.3389/fcvm.2026.1920900.s001</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Supplementary_file_1_Expanding_indications_for_transcatheter_aortic_valve_implantation_time_for_valve-in-valve_in_mechanical_prosthesis_A_systematic_review_and_meta-analysis_docx/33972925</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
