<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-10T17:57:14Z</responseDate>
  <request identifier="oai:figshare.com:article/33859777" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33859777</identifier>
        <datestamp>2026-09-16T15:53:23Z</datestamp>
        <setSpec>portal_1197</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Data for : Fiber-coupled Diamond Magnetometry with an Unshielded 30 pT/sqrt(Hz)) sensitivity</dc:title>
          <dc:creator>Simon Graham (760460)</dc:creator>
          <dc:creator>A. T. M. A. Rahman (14364144)</dc:creator>
          <dc:creator>L. Munn (14364147)</dc:creator>
          <dc:creator>R. L. Patel (14364150)</dc:creator>
          <dc:creator>A. J. Newman (14364153)</dc:creator>
          <dc:creator>Colin J. Stephen (17493036)</dc:creator>
          <dc:creator>A. Nikitin Colston (24994267)</dc:creator>
          <dc:creator>A. M. Edmonds (14364162)</dc:creator>
          <dc:creator>D. J. Twitchen (14364165)</dc:creator>
          <dc:creator>M. L. Markham (16145327)</dc:creator>
          <dc:creator>Gavin Morley (6564578)</dc:creator>
          <dc:subject>Migrated from ePrints</dc:subject>
          <dc:description>Ensembles of nitrogen-vacancy centers (NVCs) in diamond can be employed for sensitive magnetometry. In this work, we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 ± 10) pT/ √Hz in a (10–500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red-photon conversion efficiency, the use of a [100] bias-field alignment, microwave and lock-in amplifier (LIA) parameter optimization, as well as a balanced hyperfine-excitation scheme. Furthermore, a silicon carbide (SiC) heat spreader is used for microwave delivery, alongside low-strain 1-mm3 12C diamonds, one of which is placed in a second magnetically insensitive fluorescence-collecting sensor head for common-mode noise cancellation. The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with some orientation dependence but no complete dead zones, demonstrating its potential for use in remote-sensing applications.&lt;br&gt;&lt;br&gt;Data record consisting of a zip file. ODMR and time-trace data in .mat form. Test-field measurements and vector analyser data in .csv form.</dc:description>
          <dc:date>2023-04-14T00:00:00Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.82444/warw.33859777.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Data_for_Fiber-coupled_Diamond_Magnetometry_with_an_Unshielded_30_pT_sqrt_Hz_sensitivity/33859777</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>