<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-14T21:49:01Z</responseDate>
  <request identifier="oai:figshare.com:article/33820660" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33820660</identifier>
        <datestamp>2026-09-15T19:57:04Z</datestamp>
        <setSpec>portal_1197</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>National Grid frequency trace</dc:title>
          <dc:creator>Robert S. MacKay (24749182)</dc:creator>
          <dc:subject>Frequencies of oscillating systems</dc:subject>
          <dc:subject>National Grid Company</dc:subject>
          <dc:subject>Electric power systems</dc:subject>
          <dc:subject>Linear models (Statistics)</dc:subject>
          <dc:subject>Stochastic processes -- Mathematical models</dc:subject>
          <dc:subject>Migrated from ePrints</dc:subject>
          <dc:description>The dataset provides the GB grid frequency every second for two hours (02.00-04.00) on 1 September 2015 (at some location that I do not remember).  I used it to test some linear stochastic process models for the frequency as a function of time.  On the 2-hour timescale the trace fit reasonably well to an Ornstein-Uhlenbeck (OU) process with a decay time of around 30 minutes.  On a shorter timescale, in particular the first 3 minutes 20 seconds, the trace looked smooth so I fitted it to a first-order filtered OU process, which gave me time constants of 11 minutes and 1.9 seconds.  This was important evidence that a useful model for power imbalance as a function of time is a filtered white noise.  Furthermore, the power spectrum of the 2-hour trace showed a regime with slope around -4 for periods shorter than 25 seconds, consistent with being a first-order filtered OU process, until the Nyquist cutoff at 2 seconds.&lt;br&gt;&lt;br&gt;Data record consists of the raw data in an attached spreadsheet. The dataset provides the GB grid frequency every second for two hours (02.00-04.00) on 1 September 2015 (location undisclosed). The data were publicly available from National Grid (http://www2.nationalgrid.com/Enhanced-Frequency-Response.aspx) at the time of original download. No changes have been made to the data. The data are in an excel file with three columns: date (DD/MM/YEAR), time (HH:MM:SS), frequency (Hz).  A graph is also provided.</dc:description>
          <dc:date>2026-09-15T19:57:04Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.82444/warw.33820660.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/National_Grid_frequency_trace/33820660</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>