<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-14T01:35:15Z</responseDate>
  <request identifier="oai:figshare.com:article/33753856" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33753856</identifier>
        <datestamp>2026-09-14T19:28:45Z</datestamp>
        <setSpec>category_26482</setSpec>
        <setSpec>category_26779</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Benchmark Matrix: Inductive Motor Locked Rotor Amperes (LRA), Inrush Surge Multipliers, and Backup Generator Sizing Envelopes</dc:title>
          <dc:creator>Miad Saadidi (24671005)</dc:creator>
          <dc:subject>Electrical engineering not elsewhere classified</dc:subject>
          <dc:subject>Mechanical engineering not elsewhere classified</dc:subject>
          <dc:subject>Electrical transients</dc:subject>
          <dc:description>&lt;p dir="ltr"&gt;### Overview &amp; Physical Modeling Scope&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;This benchmark tabular dataset provides empirical and analytical engineering matrices for single-phase alternating-current (AC) inductive motor starting transients, Locked Rotor Amperes (LRA), Full Load Amperes (FLA), starting power factors (cos φ), and emergency generator sizing envelopes under NEMA MG-1 and NFPA 70 (NEC) standards.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;During electrical startup (0 RPM), induction motors produce zero counter-electromotive force (back-EMF), drawing peak inrush currents 4.5x to 7.0x higher than rated continuous running current across the first 100 to 300 milliseconds. This dataset models continuous running wattage, instantaneous surge volt-amperes, electronic soft-starter current mitigation (-65% to -70% reduction), and minimum recommended generator surge/continuous capacities across residential HVAC compressors, deep well pumps, sump pumps, and workshop machinery.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;### Tabular Data Schema Dictionary&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;* **appliance_id** (string): Unique alphanumeric equipment identifier.&lt;/p&gt;&lt;p dir="ltr"&gt;* **equipment_name** (string): Standard engineering equipment name and physical capacity rating.&lt;/p&gt;&lt;p dir="ltr"&gt;* **equipment_category** (string): Functional categorization (`HVAC`, `Water_Pumping`, `Drainage`, `Pneumatic`, `Refrigeration`, `Machinery`, `Recreation`).&lt;/p&gt;&lt;p dir="ltr"&gt;* **nominal_hp** (float): Mechanical horsepower equivalent.&lt;/p&gt;&lt;p dir="ltr"&gt;* **voltage_v** (integer): Nominal operating AC line voltage (120V or 240V split-phase, 60 Hz).&lt;/p&gt;&lt;p dir="ltr"&gt;* **nema_code_letter** (string): NEMA MG-1 locked-rotor kVA/HP designation (Code Letters G through L).&lt;/p&gt;&lt;p dir="ltr"&gt;* **kva_per_hp_range** (string): Standard starting kVA per rated horsepower bracket under NEMA MG-1 Section 10.37.&lt;/p&gt;&lt;p dir="ltr"&gt;* **running_fla_amps** (float): Rated continuous full-load current in Amperes.&lt;/p&gt;&lt;p dir="ltr"&gt;* **running_watts** (integer): Steady-state active real electrical power consumption in Watts.&lt;/p&gt;&lt;p dir="ltr"&gt;* **lra_starting_amps** (float): Peak locked-rotor inrush starting current in Amperes.&lt;/p&gt;&lt;p dir="ltr"&gt;* **inrush_multiplier** (float): Ratio of starting current to running current (`lra_starting_amps / running_fla_amps`).&lt;/p&gt;&lt;p dir="ltr"&gt;* **peak_starting_watts** (integer): Instantaneous starting volt-ampere demand in Watts/VA.&lt;/p&gt;&lt;p dir="ltr"&gt;* **inductive_surge_delta_watts** (integer): Net starting surge step over running wattage (`peak_starting_watts - running_watts`).&lt;/p&gt;&lt;p dir="ltr"&gt;* **soft_start_mitigated_lra_amps** (float): Starting current in Amperes when modulated by a closed-loop electronic soft starter.&lt;/p&gt;&lt;p dir="ltr"&gt;* **soft_start_peak_watts** (integer): Peak starting demand with soft starter in Watts.&lt;/p&gt;&lt;p dir="ltr"&gt;* **min_recommended_generator_continuous_w** (integer): Minimum continuous generator capacity in Watts.&lt;/p&gt;&lt;p dir="ltr"&gt;* **min_recommended_generator_surge_w** (integer): Minimum alternator transient surge capacity in Watts.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;### Governing Standards &amp; Methodology&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;* **NEMA MG 1-2021:** Motors and Generators (Section 10.37 Code Letters for Locked-Rotor kVA).&lt;/p&gt;&lt;p dir="ltr"&gt;* **NFPA 70 / National Electrical Code (NEC 2023):** Article 430 (Motors, Motor Circuits, and Controllers).&lt;/p&gt;&lt;p dir="ltr"&gt;* **IEEE Std 399-1997:** IEEE Recommended Practice for Industrial and Commercial Power Systems Analysis.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;All mathematical formulas and interactive simulation workbenches are open-access and reproducible at https://www.powelab.org/home-energy/generator-size-calculator.&lt;/p&gt;</dc:description>
          <dc:date>2026-09-14T19:28:45Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.6084/m9.figshare.33753856.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Benchmark_Matrix_Inductive_Motor_Locked_Rotor_Amperes_LRA_Inrush_Surge_Multipliers_and_Backup_Generator_Sizing_Envelopes/33753856</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>