      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Benchmark Matrix: Building Envelope Thermal Transmission, Fenestration SHGC, and Infiltration Sizing per ACCA Manual J</dc:title>
          <dc:creator>Miad Saadidi (24671005)</dc:creator>
          <dc:subject>Mechanical engineering not elsewhere classified</dc:subject>
          <dc:subject>HVAC system runtime</dc:subject>
          <dc:description>&lt;p dir="ltr"&gt;### 1. Overview &amp; Experimental Bounds&lt;/p&gt;&lt;p dir="ltr"&gt;This open-access benchmark matrix compiles 540 deterministic residential building envelope thermal load scenarios calculated in accordance with ACCA Manual J (8th Edition, Full Version) and the ASHRAE Handbook of Fundamentals. The dataset provides empirical and computational baselines evaluating Fourier conductive heat transmission across composite multi-layer wall and roof assemblies, fenestration Solar Heat Gain Coefficients (SHGC), and pressure-driven envelope infiltration converted from blower door depressurization tests (ACH50).&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;Scenarios evaluate multi-dimensional variations across:&lt;/p&gt;&lt;p dir="ltr"&gt;- 5 ASHRAE Climate Zones (CZ-2 through CZ-6) spanning design conditions from -15°F winter design dry-bulb to 95°F summer design dry-bulb.&lt;/p&gt;&lt;p dir="ltr"&gt;- 4 Wall Assembly Configurations spanning legacy uninsulated 2x4 framing (effective U = 0.106) through advanced 2x6 framing and continuous exterior polyisocyanurate insulation (effective U = 0.040) with 2D framing factor thermal bridging.&lt;/p&gt;&lt;p dir="ltr"&gt;- 3 Fenestration Regimes: Legacy single clear aluminum (U = 1.05, SHGC = 0.72), double clear metal (U = 0.48, SHGC = 0.58), and high-performance double low-E argon vinyl (U = 0.28, SHGC = 0.24).&lt;/p&gt;&lt;p dir="ltr"&gt;- 3 Envelope Tightness Regimes: Leaky legacy (8.5 ACH50), code baseline (3.5 ACH50), and aerosol-sealed high performance (1.2 ACH50) converted via Sherman-Grimsrud LBL correlation factors (N = 18.2).&lt;/p&gt;&lt;p dir="ltr"&gt;- 3 Dwelling Archetypes: Compact (1,500 sq ft), suburban (2,500 sq ft), and large (3,600 sq ft).&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;Each state vector computes peak heating loss, sensible cooling gain, latent moisture cooling load, total refrigeration capacity required (tons), and quantifies the empirical over-prediction percentage of legacy contractor heuristics ("500 sq ft per ton").&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;### 2. Tabular Schema Dictionary&lt;/p&gt;&lt;p dir="ltr"&gt;- `scenario_id` (string): Unique state point identifier (ENV-0001 to ENV-0540)&lt;/p&gt;&lt;p dir="ltr"&gt;- `climate_zone` (string): ASHRAE Standard 169 climate zone code (CZ-2 to CZ-6)&lt;/p&gt;&lt;p dir="ltr"&gt;- `climate_zone_name` (string): Climate zone geographic and humidity descriptor&lt;/p&gt;&lt;p dir="ltr"&gt;- `outdoor_winter_db_f` (integer): ASHRAE 99% design winter dry-bulb temperature (°F)&lt;/p&gt;&lt;p dir="ltr"&gt;- `outdoor_summer_db_f` (integer): ASHRAE 1% design summer dry-bulb temperature (°F)&lt;/p&gt;&lt;p dir="ltr"&gt;- `outdoor_summer_wb_f` (integer): ASHRAE mean coincident summer wet-bulb temperature (°F)&lt;/p&gt;&lt;p dir="ltr"&gt;- `indoor_winter_setpoint_f` (integer): Heating thermostat setpoint (70°F)&lt;/p&gt;&lt;p dir="ltr"&gt;- `indoor_summer_setpoint_f` (integer): Cooling thermostat setpoint (75°F)&lt;/p&gt;&lt;p dir="ltr"&gt;- `floor_area_sqft` (integer): Conditioned floor area (sq ft)&lt;/p&gt;&lt;p dir="ltr"&gt;- `dwelling_volume_cuft` (integer): Conditioned interior air volume (cu ft)&lt;/p&gt;&lt;p dir="ltr"&gt;- `wall_assembly_id` (string): Structural wall framing and insulation specification&lt;/p&gt;&lt;p dir="ltr"&gt;- `wall_effective_u_factor` (float): Effective assembly overall heat transfer coefficient incorporating 2D framing thermal bridging (BTU/(hr*ft²*°F))&lt;/p&gt;&lt;p dir="ltr"&gt;- `fenestration_id` (string): Window glazing, spacer, and frame assembly designation&lt;/p&gt;&lt;p dir="ltr"&gt;- `fenestration_u_factor` (float): Fenestration overall U-factor per NFRC rating (BTU/(hr*ft²*°F))&lt;/p&gt;&lt;p dir="ltr"&gt;- `fenestration_shgc` (float): Fenestration Solar Heat Gain Coefficient (dimensionless)&lt;/p&gt;&lt;p dir="ltr"&gt;- `infiltration_ach50` (float): Blower door depressurization air leakage rate at 50 Pa (ACH50)&lt;/p&gt;&lt;p dir="ltr"&gt;- `infiltration_design_cfm` (float): Converted natural infiltration design airflow via Sherman-Grimsrud correlation (CFM)&lt;/p&gt;&lt;p dir="ltr"&gt;- `heating_conduction_loss_btu_h` (integer): Total conductive Fourier heat loss across walls, glass, roof, and slab (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `heating_infiltration_loss_btu_h` (integer): Sensible air infiltration heating power required (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `total_peak_heating_load_btu_h` (integer): Total peak design heating demand (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `summer_conduction_gain_btu_h` (integer): Peak sensible conductive heat gain incorporating sol-air exterior solar radiation (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `summer_fenestration_solar_gain_btu_h` (integer): Direct and diffuse solar radiation through fenestration with interior shading (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `summer_sensible_infiltration_btu_h` (integer): Sensible air infiltration cooling load (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `summer_internal_sensible_gain_btu_h` (integer): Internal equipment, lighting, and occupant sensible metabolic load (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `total_cooling_sensible_load_btu_h` (integer): Net peak sensible heat extraction requirement (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `total_cooling_latent_load_btu_h` (integer): Moisture infiltration and occupant latent respiration load (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `total_cooling_peak_load_btu_h` (integer): Total peak cooling design capacity (BTU/hr)&lt;/p&gt;&lt;p dir="ltr"&gt;- `calculated_cooling_tonnage` (float): Deterministic ACCA Manual J cooling equipment capacity (tons)&lt;/p&gt;&lt;p dir="ltr"&gt;- `rule_of_thumb_tonnage_500sqft` (float): Capacity predicted by legacy 500 sq ft/ton heuristic (tons)&lt;/p&gt;&lt;p dir="ltr"&gt;- `heuristic_oversize_percentage` (float): Equipment oversizing error produced by legacy heuristic relative to deterministic physics (%)&lt;/p&gt;&lt;p dir="ltr"&gt;- `sensible_heat_ratio_shr` (float): Ratio of sensible cooling load to total cooling load (dimensionless)&lt;/p&gt;&lt;p dir="ltr"&gt;- `canonical_reference_url` (string): Canonical interactive reference engine&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;### 3. Governing Standards Cited&lt;/p&gt;&lt;p dir="ltr"&gt;- ACCA Manual J (8th Edition, Full Technical Version): Residential Load Calculation&lt;/p&gt;&lt;p dir="ltr"&gt;- ASHRAE Handbook of Fundamentals (Chapters 14, 16, 17, 18, 27)&lt;/p&gt;&lt;p dir="ltr"&gt;- ASHRAE Standard 90.1-2022: Energy Standard for Sites and Buildings&lt;/p&gt;&lt;p dir="ltr"&gt;- IECC 2021 / 2024: International Energy Conservation Code&lt;/p&gt;&lt;p dir="ltr"&gt;- ASTM E779: Standard Test Method for Determining Air Leakage Rate by Fan Pressurization&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;### 4. Computational Reference&lt;/p&gt;&lt;p dir="ltr"&gt;Interactive simulation workbenches, deterministic calculation engines, and companion verification tools are maintained at https://hvaclogic.org/calculators/btu-calculator and https://hvaclogic.org/calculators/r-value-calculator.&lt;/p&gt;</dc:description>
          <dc:date>2026-09-13T14:02:57Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.6084/m9.figshare.33702643.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Benchmark_Matrix_Building_Envelope_Thermal_Transmission_Fenestration_SHGC_and_Infiltration_Sizing_per_ACCA_Manual_J/33702643</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>