<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-07T04:59:38Z</responseDate>
  <request identifier="oai:figshare.com:article/33640444" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33640444</identifier>
        <datestamp>2026-09-11T20:43:14Z</datestamp>
        <setSpec>category_26779</setSpec>
        <setSpec>category_24952</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Next-Generation Low-GWP Refrigerant Line-Set Mass Addition and Velocity Gradient Benchmark Dataset: 816 Thermodynamic Test Configurations</dc:title>
          <dc:creator>Miad Saadidi (24671005)</dc:creator>
          <dc:subject>Mechanical engineering not elsewhere classified</dc:subject>
          <dc:subject>Building science, technologies and systems</dc:subject>
          <dc:subject>Refrigerant charge</dc:subject>
          <dc:description>&lt;p dir="ltr"&gt;This benchmark dataset contains 816 deterministic calculation points modeling liquid refrigerant mass addition and hydrostatic elevation lift penalties for residential and commercial unitary split systems. Evaluated refrigerants include next-generation low-GWP A2L blends (R-454B, R-32) and legacy R-410A across standardized ASTM B280 liquid line diameters (1/4", 5/16", 3/8", 1/2"), line-set lengths from 15 ft to 150 ft, and vertical elevation risers up to 45 ft.&lt;/p&gt;&lt;p&gt;&lt;br&gt;&lt;/p&gt;&lt;p dir="ltr"&gt;Each scenario computes net adder mass (oz), total operating charge (oz, lbs, kg), and flags ASHRAE Standard 15 oil return trap requirements.&lt;/p&gt;&lt;p dir="ltr"&gt;Reference Computational Engine: https://hvaclogic.org/calculators/refrigerant-charge-calculator&lt;/p&gt;&lt;p dir="ltr"&gt;Technical Methodology: https://hvaclogic.org/methodology&lt;/p&gt;&lt;p dir="ltr"&gt;Companion Research Paper: https://hvaclogic.org/research&lt;/p&gt;</dc:description>
          <dc:date>2026-09-11T20:43:14Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.6084/m9.figshare.33640444.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Next-Generation_Low-GWP_Refrigerant_Line-Set_Mass_Addition_and_Velocity_Gradient_Benchmark_Dataset_816_Thermodynamic_Test_Configurations/33640444</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>