<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-13T13:38:11Z</responseDate>
  <request identifier="oai:figshare.com:article/33395062" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33395062</identifier>
        <datestamp>2026-09-17T12:06:44Z</datestamp>
        <setSpec>category_32963</setSpec>
        <setSpec>portal_1075</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Supplemental Material-Table SI</dc:title>
          <dc:creator>Yue Hui (4478452)</dc:creator>
          <dc:creator>Zhenyu Zhang (384880)</dc:creator>
          <dc:creator>Ming Zhuang (5626481)</dc:creator>
          <dc:creator>Hao Wu (65943)</dc:creator>
          <dc:creator>Xin Liang (442470)</dc:creator>
          <dc:subject>Engineering</dc:subject>
          <dc:subject>Gir-assisted atomization</dc:subject>
          <dc:description>Table SⅠ Uncertainties of droplet Sauter mean diameter in various conditions.
(ALT text: Data table listing the measurement uncertainties of droplet Sauter mean diameter (D32) across axial distances x from 30 mm to 140 mm (in 10 mm increments) under various injection strategies. It compares the Fuel Pilot Injection (FPI) strategy (uncertainties ranging between 0.0166 and 0.0622) with the Gas Leading Injection (GLI) strategy across advance times T1 = 0, 1, 2, 3, and 4 ms (with uncertainties generally lower, mostly between 0.0025 and 0.0252, and reaching 0.0520 at x = 30 mm).)</dc:description>
          <dc:date>2026-09-17T12:06:44Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.60893/figshare.pof.33395062.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Supplemental_Material-Table_SI/33395062</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>