<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-07T16:41:27Z</responseDate>
  <request identifier="oai:figshare.com:article/33170660" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/33170660</identifier>
        <datestamp>2026-09-23T14:30:12Z</datestamp>
        <setSpec>category_26308</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_09_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Supporting data for "Automated generation of experimentally calibrated digital twins for desiccant-based low-dew-point air-conditioning systems from declarative topology specifications"</dc:title>
          <dc:creator>Younghwan Joo (21659789)</dc:creator>
          <dc:creator>Jeonghoon Han (1592818)</dc:creator>
          <dc:creator>Sang Hyun Oh (24523536)</dc:creator>
          <dc:creator>Soosik Bang (24523540)</dc:creator>
          <dc:creator>Sung-il Kim (633593)</dc:creator>
          <dc:subject>Chemical and thermal processes in energy and combustion</dc:subject>
          <dc:subject>Desiccant wheel dehumidification</dc:subject>
          <dc:subject>Low-dew-point air conditioning</dc:subject>
          <dc:subject>Heat and mass transfer</dc:subject>
          <dc:subject>Digital twin</dc:subject>
          <dc:subject>Automated model generation</dc:subject>
          <dc:description>&lt;p dir="ltr"&gt;Measurement, validation and specification data supporting the paper "Automated generation of experimentally calibrated digital twins for desiccant-based low-dew-point air-conditioning systems from declarative topology specifications" (Joo, Han, Oh, Bang and Kim; revised manuscript). The case-study system is an industrial low-dew-point air-handling system built around a commercial desiccant wheel whose sorbent is undisclosed by the manufacturer, operated with the dehumidification unit on and off.&lt;/p&gt;&lt;p dir="ltr"&gt;This release (package release 3) replaces the earlier archive. It contains the humidity and electric-power measurements with their window statistics; the logged record of every measurement window used for calibration and comparison (frost and dew points, airflows, regeneration temperature and heater power at a nominal PLC logging interval of 15 s, with the irregular retained timestamp intervals documented); the closed-loop frost-point time series used for the terminal-rate equilibrium assessment; the operational summaries of the input-change sessions; the parameter-perturbation study behind the local sensitivity analysis; the sorbent-screening, isotherm-fit and lookup-resolution checks behind the isotherm-base selection; and the specification side of the framework: the schema of the topology specification language, the three case-study specifications as run (dehumidification on; dehumidification off, named bypass in the archive; and the isolated wheel), their difference, the build reports the generator emits, and the interface definitions (ports and mask parameters) of the library blocks they instantiate. A data dictionary maps each channel to the corresponding node in the paper and documents the conditioning applied to the raw channels, including the correction of the regeneration-heater power channel for the metering configuration reported in the paper. The README lists what changed since the earlier releases, including the withdrawn two-bank heater interpretation, the recalibrated parameter set, and the corrected definition of the dehumidification-off measurement window. The generator, the Simulink implementation of the component blocks and the generated models are not included.&lt;/p&gt;</dc:description>
          <dc:date>2026-09-23T14:30:12Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.6084/m9.figshare.33170660.v2</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Supporting_data_for_Automated_generation_of_experimentally_validated_digital_twins_for_desiccant-based_low-dew-point_air-conditioning_systems_from_declarative_topology_specifications_/33170660</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>