<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-12T04:39:32Z</responseDate>
  <request identifier="oai:figshare.com:article/32628360" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/32628360</identifier>
        <datestamp>2026-10-01T17:40:18Z</datestamp>
        <setSpec>portal_1172</setSpec>
        <setSpec>item_type_8</setSpec>
        <setSpec>month_year_10_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>A combined experimental and computational framework to optimise processing and design of poly(L-lactic acid) bioresorbable stents</dc:title>
          <dc:creator>Ross Blair (12695843)</dc:creator>
          <dc:subject>PUREID: 189879681</dc:subject>
          <dc:subject>coronary stents</dc:subject>
          <dc:subject>poly(L-lactic acid)</dc:subject>
          <dc:subject>biaxial stretching</dc:subject>
          <dc:subject>constitutive modelling</dc:subject>
          <dc:subject>multi-objective optimisation</dc:subject>
          <dc:description>Coronary heart disease, caused by inflammatory hardening and narrowing of arteries (atherosclerosis) is the largest cause of death in the world. Coronary stents, used to treat atherosclerosis, are typically manufactured from high strength metallic alloys; however such devices remain in the body permanently and can trigger undesirable immunological responses. Bioresorbable polymer stents offer an attractive solution, providing a temporary scaffold that resorbs once the artery heals. However, polymeric stents are mechanically inferior to their metallic counterparts, requiring thicker struts to provide equivalent radial support, which has been shown to cause elevated rates of thrombosis. This thesis aims to address the challenge of designing mechanically effective but sufficiently thin bioresorbable polymer stents through multi-objective optimisation of material parameters and stent geometry.&lt;br&gt;&lt;br&gt;Initially, the processing history of a polymeric coronary stent was replicated using a custom-built biaxial tensile test machine in order to assess the improvement in short-term (pre-degradation) mechanical properties of extruded poly(L-lactic acid) (PLLA). Results of an extensive experimental programme to characterise the post­ processing material properties of PLLA indicated that biaxial deformation has the potential to enhance the elastic modulus and yield strength of extruded PLLA sheet by approximately 80% and 70%, through selection of optimal processing conditions. Both elastic modulus and yield strength were highly dependent on the  aspect  ratio of the biaxial deformation. Response surface methodology was used to provide empirical correlations between aspect ratio and these mechanical properties. Using these empirical correlations, a rate-independent, transversely isotropic, temperature­ dependent, elastic-plastic PLLA constitutive model was calibrated for finite element implementation.&lt;br&gt;&lt;br&gt;Finally, an optimisation framework was developed that  considered  the  combined  effect of the biaxial stretching processing history and  the  geometric  configuration when optimising the mechanical performance of a PLLA coronary stent. Forty parametric stent designs were generated by varying the aspect ratio of the biaxial deformation, along with the strut width,  the  strut  thickness  and  the  strut  length.  Each stent design was evaluated  computationally,  using  finite  element  analysis, across a series of performance metrics: the cross-sectional area post-dilation, foreshortening, stent-to-artery ratio and radial collapse pressure. Pareto fronts highlighted that a change in one design parameter that  improves  one  metric  often leads to a compromise in at least one of the other metrics.  Based  on  the  results of these simulations, a set of statistical surrogate models were  established  that  related each performance metric to the design parameters. An objective function was constructed that sought to minimise foreshortening and stent-to-artery ratio whilst maximising cross-sectional area post-dilation and radial collapse pressure. Multi­ objective optimisation was conducted using the surrogate models  to  produce  an optimal poly(L-lactic acid) stent  design  that  offered  improved  performance  relative to a baseline design for the same strut thickness.&lt;br&gt;&lt;br&gt;In summary, this thesis addresses key limitations in polymeric stent design and the results may be used to aid in the development of high stiffness, thin strut polymeric stents.</dc:description>
          <dc:date>2026-10-01T17:40:18Z</dc:date>
          <dc:type>Text</dc:type>
          <dc:type>Thesis</dc:type>
          <dc:identifier>10.17034/32628360.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/thesis/A_combined_experimental_and_computational_framework_to_optimise_processing_and_design_of_poly_L-lactic_acid_bioresorbable_stents/32628360</dc:relation>
          <dc:rights>All Rights Reserved</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
