<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-09-19T02:20:05Z</responseDate>
  <request identifier="oai:figshare.com:article/31151707" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/31151707</identifier>
        <datestamp>2026-01-27T10:44:05Z</datestamp>
        <setSpec>portal_1132</setSpec>
        <setSpec>item_type_8</setSpec>
        <setSpec>month_year_01_2026</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Self-Powered Wearable Sweat Monitoring  using 2D WS2 Textile Integrated  Triboelectric Nanogenerators for Future  Personalized Healthcare</dc:title>
          <dc:creator>Mashael Habab Albuqami (21043925)</dc:creator>
          <dc:subject>Triboelectric nanogenerators</dc:subject>
          <dc:subject>Tungsten disulfide</dc:subject>
          <dc:subject>Biosensors</dc:subject>
          <dc:subject>Wearable sensors</dc:subject>
          <dc:subject>Self-powered sensors</dc:subject>
          <dc:subject>Uric acid detection</dc:subject>
          <dc:subject>Sweat analysis</dc:subject>
          <dc:subject>2D materials</dc:subject>
          <dc:subject>Smart textiles</dc:subject>
          <dc:subject>Cortisol detection</dc:subject>
          <dc:description>The growing global burden of chronic diseases such as diabetes, cardiovascular 
disorders, and neurological conditions highlight the urgent need for continuous, 
non-invasive health monitoring solutions. Sweat-based sensing has emerged as 
a promising alternative to traditional diagnostic approaches, offering a rich source 
of biomarkers including electrolytes, metabolites, and stress-related molecules 
such as cortisol. However, conventional laboratory-based methods are 
unsuitable for real-time monitoring, prompting the development of wearable 
biosensors. This PhD thesis explores a novel class of self-powered wearable 
biosensors using two-dimensional tungsten disulfide (2D WS2) integrated into 
textile-based self-powered triboelectric nanogenerators (TENGs) devices.
The research introduces a novel fabrication approach for creating self powered biosensors by integrating 2D WS2 into textile substrates. 2D WS2 was 
produced via liquid-phase exfoliation and deposited onto fabrics using three 
methods: ultrasonic spray coating, drop casting, and immersion. Among these, 
spray coating emerged as the optimal technique due to its superior film uniformity, 
reproducibility, and mechanical robustness under flexural strain. This approach 
enabled the creation of TENGs tailored for sweat sensing applications while 
preserving the textile’s flexibility and wearability. The concept of "electronic 
dyeing" was also introduced, wherein 2D WS2 imparts functional electronic 
characteristics to textiles in a similar manner to how traditional dyes impart colour, 
allowing scalable integration of sensing functionalities directly onto wearable 
fabrics.
The 2D WS2-coated textiles were first evaluated for sweat sensing 
performance using phosphate-buffered saline (PBS) to simulate physiological 
sweat conditions. Devices were subjected to triboelectric testing under varying 
humidity conditions and volumes of PBS to assess stability, output consistency, 
and the impact of fluid exposure. The results revealed that polyester fabrics 
coated with 2D WS2 and paired with polyethylene terephthalate (PET) as the 
counter layer showed the most stable and reproducible performance. 
Building upon the successful platform for model sweat sensing, the 
research progressed to selectively detect uric acid, a key biomarker of metabolic 
function and oxidative stress, using 2D WS2 -based TENGs. Uric acid 
concentrations ranging from 10 µM to 20 mM were tested, encompassing both 
5
physiologically normal and pathologically elevated levels. The biosensor, 
composed of a 2D WS2-coated textile paired with a PET counter layer, 
demonstrated consistent, linear changes in triboelectric outputs including open circuit voltage, short-circuit current, and transferred charge across this range. 
This work marks the first demonstration of a textile-based, energy-autonomous 
device capable of detecting uric acid without requiring external power, offering a 
low-maintenance, wearable solution for real-time metabolic health monitoring.
The final phase of the work addressed the detection of cortisol, a critical 
biomarker for stress and fatigue. The biosensor was tested across cortisol 
concentrations from 100 ng/mL to 1 mg/mL, capturing both normal and elevated 
physiological levels. Output signals were recorded under controlled mechanical 
actuation and simulated biomechanical motion to reflect realistic use scenarios. 
The device demonstrated a peak response at 200 ng/mL, consistent with typical 
human stress-induced cortisol levels, and maintained reliable performance even 
at ultra-high concentrations. 
Collectively, these findings establish a robust, wearable platform capable 
of detecting multiple sweat biomarkers through scalable fabrication and self powered operation, aligning with the future vision of personalized, preventive 
healthcare.&lt;p&gt;&lt;/p&gt;</dc:description>
          <dc:date>2026-01-26T00:00:00Z</dc:date>
          <dc:type>Text</dc:type>
          <dc:type>Thesis</dc:type>
          <dc:identifier>10779/exe.31151707.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/thesis/Self-Powered_Wearable_Sweat_Monitoring_using_2D_WS2_Textile_Integrated_Triboelectric_Nanogenerators_for_Future_Personalized_Healthcare/31151707</dc:relation>
          <dc:rights>All rights reserved</dc:rights>
          <dc:rights>Open Access after 2027-07-26</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>