<?xml version='1.0' encoding='utf-8'?>
<?xml-stylesheet type="text/xsl" href="/v2/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-15T07:32:44Z</responseDate>
  <request identifier="oai:figshare.com:article/26326519" metadataPrefix="oai_dc" verb="GetRecord">https://api.figshare.com/v2/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:figshare.com:article/26326519</identifier>
        <datestamp>2024-08-21T15:06:15Z</datestamp>
        <setSpec>category_26470</setSpec>
        <setSpec>portal_918</setSpec>
        <setSpec>item_type_3</setSpec>
        <setSpec>month_year_08_2024</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"  xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Partial Discharge Monitoring of C3F7CN/CO2 Mixture Retrofilled in Gas Insulated Busbar</dc:title>
          <dc:creator>Maria-Irina Oancea (19171384)</dc:creator>
          <dc:subject>Electrical energy transmission, networks and systems</dc:subject>
          <dc:subject>Gas insulated line (GIL)</dc:subject>
          <dc:subject>gas insulated switchgear (GIS)</dc:subject>
          <dc:subject>gas insulated busbar (GIB)</dc:subject>
          <dc:subject>partial discharge</dc:subject>
          <dc:subject>sulfur hexafluoride</dc:subject>
          <dc:subject>SF6 alternatives</dc:subject>
          <dc:subject>UHF measurements</dc:subject>
          <dc:description>&lt;p dir="ltr"&gt;Condition monitoring of gas insulated high voltage equipment is important to ensure reliable operation of electricity networks. Partial discharge (PD) monitoring is well established for existing SF&lt;sub&gt;6&lt;/sub&gt; equipment, but still in its infancy for the emerging SF&lt;sub&gt;6&lt;/sub&gt; alternatives as the power industry transitions from SF&lt;sub&gt;6­­&lt;/sub&gt;. PD characteristics of 20% C&lt;sub&gt;3&lt;/sub&gt;F&lt;sub&gt;7&lt;/sub&gt;CN / 80% CO&lt;sub&gt;2&lt;/sub&gt; gas mixture as a viable retrofill solution were extensively investigated over extended energization periods in a busbar demonstrator designed for SF&lt;sub&gt;6&lt;/sub&gt; and rated to 420/550 kV. Protrusions of 3, 5, 10 and 15 mm needle lengths were used on the high voltage conductor for comparative PD investigations of SF&lt;sub&gt;6&lt;/sub&gt; and 20% C&lt;sub&gt;3&lt;/sub&gt;F&lt;sub&gt;7&lt;/sub&gt;CN / 80% CO&lt;sub&gt;2&lt;/sub&gt; gas mixture. PD activity was measured with IEC 60270 (apparent charge) and ultra-high frequency (UHF) detection methods. The PD patterns recorded for all needle lengths were representative of a protrusion-on-conductor defect and the two PD detection methods were comparable. For identical defect lengths, SF&lt;sub&gt;6&lt;/sub&gt; showed a comparatively longer time-to-breakdown when compared to a 20% C&lt;sub&gt;3&lt;/sub&gt;F&lt;sub&gt;7&lt;/sub&gt;CN / 80% CO&lt;sub&gt;2&lt;/sub&gt; mixture. Results obtained in a controlled laboratory environment demonstrate wider applicability to field measurements of C&lt;sub&gt;3&lt;/sub&gt;F&lt;sub&gt;7&lt;/sub&gt;CN based mixtures adopted for retrofill application in SF&lt;sub&gt;6&lt;/sub&gt;-designed gas insulated busbar.&lt;/p&gt;</dc:description>
          <dc:date>2024-08-21T15:06:15Z</dc:date>
          <dc:type>Dataset</dc:type>
          <dc:type>Dataset</dc:type>
          <dc:identifier>10.48420/26326519.v1</dc:identifier>
          <dc:relation>https://figshare.com/articles/dataset/Partial_Discharge_Monitoring_of_C3F7CN_CO2_Mixture_Retrofilled_in_Gas_Insulated_Busbar/26326519</dc:relation>
          <dc:rights>CC BY 4.0</dc:rights>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>